1.
Rev. gaúch. enferm ; 43(spe): e20220117, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BDENF | ID: biblio-1409418

RESUMO

ABSTRACT Objective To describe and compare the physiological signs presented by premature infants in traditional and humanized weighing. Method A quasi-experimental crossover study, with a sample of 30 premature infants randomly assigned and allocated to the control group (traditional) and the intervention group (humanized), from March 2019 to March 2020, with the collection of general data, vital signs before and after the procedures. Statistical analyses included description of relative and absolute frequencies, measure of central tendency and dispersion. Results Premature infants showed less increase in heart rate (53.3%) and respiratory rate (43%) in the verification of humanized weighing than in the traditional way, with 83.3% of neonates and 80%, respectively. Conclusion It was observed that the humanized form provided less physiological instability, especially in heart and respiratory rates, making it necessary to encourage discussions about the humanization of care and perform this practice routinely in health units.


RESUMEN Objetivo Describir y comparar los signos fisiológicos que presentan los recién nacidos prematuros en pesaje tradicional y humanizado. Método Estudio cuasi-experimental crossover, con una muestra de 30 prematuros asignados al azar y asignados al grupo control (tradicional) y al grupo intervención (humanizado), desde marzo 2019 hasta marzo 2020, con la recolección de datos generales, signos vitales antes y después de los procedimientos. Los análisis estadísticos incluyeron descripción de frecuencias relativas y absolutas, medida de tendencia central y dispersión. Resultados Los prematuros mostraron menor aumento de la frecuencia cardiaca (53,3%) y respiratoria (43%) en pesaje humanizada que, en la forma tradicional, con un 83,3% de neonatos y un 80%, respectivamente. Conclusión Se observó que la forma humanizada proporcionó menos inestabilidad fisiológica, especialmente en las frecuencias cardíaca y respiratoria, siendo necesario estimular discusiones sobre la humanización del cuidado y realizar esa práctica de forma rutinaria en las unidades de salud.


RESUMO Objetivo: Descrever e comparar os sinais fisiológicos apresentados pelos prematuros na pesagem tradicional e humanizada. Método: Estudo quase-experimental crossover, com amostra de 30 prematuros randomicamente assinalados e alocados no grupo controle (tradicional) e no grupo intervenção (humanizada),no período de março de 2019 a março de 2020, com a coleta de dados gerais, sinais vitais antes e depois dos procedimentos. As análises estatísticas incluíram descrição de frequências relativas e absolutas, medida de tendência central e de dispersão. Resultados: Os prematuros apresentaram menos aumento na frequência cardíaca (53,3%) e respiratória (43%) na verificação da pesagem humanizada do que na tradicional, com 83,3% dos neonatos e 80%,respectivamente. Conclusão: Observou-se que a forma humanizada proporcionou menos instabilidade fisiológica, principalmente nas frequências cardíaca e respiratória, tornando-se necessário estimular discussões sobre a humanização da assistência e realizar essa prática de forma rotineira nas unidades de saúde.

2.
Rev. bras. enferm ; 75(supl.2): e20210584, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BDENF | ID: biblio-1407459

RESUMO

ABSTRACT Objective: to describe and compare the frequency of neurobehavioral signs in preterm infants in traditional and humanized body weight check. Methods: a quantitative, quasi-experimental, cross-over study, carried out in a Neonatal Unit at a university hospital with a sample of 30 preterm newborns, randomly assigned and allocated in control group (traditional) and intervention group (humanized), with collection of general data, vital signs before and after procedures and footage. Results: there was a higher frequency of approach signs in humanized weight check compared to traditional check. Moreover, withdrawal signs were more frequent in traditional weight check compared to humanized check. Conclusion: in this regard, humanized body weight check provided greater benefits to preterm infants, making it necessary to foster discussions about humanization of care, so that this practice can be performed routinely in health units.


RESUMEN Objetivo: describir y comparar la frecuencia de signos neuroconductuales en prematuros en la verificación del peso corporal de forma tradicional y humanizada. Métodos: estudio cuantitativo, cuasiexperimental, cross-over, realizado en una Unidad Neonatal de un hospital universitario con una muestra de 30 recién nacidos prematuros, asignados aleatoriamente y asignados en el grupo control (tradicional) y en el grupo intervención (humanizado), con la recolección de datos generales, signos vitales antes y después de los procedimientos y filmaciones. Resultados: hubo mayor frecuencia de señales de acercamiento en la verificación de peso de forma humanizada en comparación con la forma tradicional. Además, los signos de retracción fueron más frecuentes en la verificación de peso de forma tradicional en comparación con la forma humanizada. Conclusión: de esa forma, la verificación del peso corporal de forma humanizada proporcionó mayores beneficios a los prematuros, siendo necesario estimular discusiones sobre la humanización de la atención, para que esa práctica pueda ser realizada de forma rutinaria en las unidades de salud.


RESUMO Objetivos: descrever e comparar a frequência dos sinais neurocomportamentais em prematuros na verificação do peso corporal de forma tradicional e humanizada. Método: estudo quantitativo, quase-experimental, tipo cross-over, realizado em uma Unidade Neonatal de um hospital universitário com amostra de 30 recém-nascidos prematuros, randomicamente assinalados e alocados no grupo controle (tradicional) e no grupo intervenção (humanizada), com a coleta de dados gerais, sinais vitais antes e depois dos procedimentos e filmagem. Resultados: observou-se uma frequência maior dos sinais de aproximação na verificação do peso de forma humanizada em relação à tradicional. Além disso, os sinais de retraimento se mostraram mais frequentes na verificação do peso de forma tradicional em comparação à humanizada. Conclusão: desse modo, a verificação do peso corporal de forma humanizada proporcionou maiores benefícios aos prematuros, tornando-se necessário estimular discussões sobre a humanização da assistência, para que esta prática possa ser realizada de forma rotineira nas unidades de saúde.